TECHNICAL DATA
Gas connection Rp ½ (½” BSP female)
Pressure test point Front left hotplate injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 13A fuse.
INSTALLATION INSTRUCTIONS
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
B
URNER
HEAT INPUT INJECTOR HEAT INPUT INJECTOR
H
OTPLATE
F
ront Left and Rear Right
3.00 kW 116 3.0 kW (220g/h) 86
H
OTPLATE
F
ront Right and Rear Left
2.0 kW 103 2.0 kW (145g/h) 70
G
rill 3.7 kW 150 (X) 3.4 kW (200g/h) 91
M
ain Oven 2.5 kW 115 2.3 kW (165g/h) 71
T
op Oven 1.9 kW 100 1.9 kW (135g/h) 66